Product model: E5EC-TQX4DSM-060
Name: Digital Counter
Brand: OMRON
Sort: RS-485 CompoWay/F lnstruction Manual
File language: English
File size: 2.32MB
Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2 E5EC-TQX4DSM-060 lnstruction Manual.
Transfer output: output (using control output).
Communication: - E5EC-TQX4DSM-060
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E5EC-TQX4DSM-060 lnstruction Manual.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5EC-TQX4DSM-060 lnstruction Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Appearance: T-shaped, slot center 7 mm.
Sensing method: Through beam type (with slot) OMRON E5EC-TQX4DSM-060 Manual.
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs) OMRON E5EC-TQX4DSM-060 Manual.
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON OMRON E5EC-TQX4DSM-060 Manual.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations.
Connector with lock that mates with commercially available,
connectors. Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Response time: 1 ms.
Sensing distance: 15 m (300 mm) (Using E39-R1),
77 m(200 mm)(Using E39-R12), 7 m (200 mm)(Using E39-R6) E5EC-TQX4DSM-060 RS-485 CompoWay/F.
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color E5EC-TQX4DSM-060 lnstruction Manual.
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Related products
OMRON
Digital temperature controller program
E5EC-TQX4ASM-080
OMRON Digital temperature controller program E5EC-TQX4ASM-080
Size: 48 x 96mm. Control output 1: voltage.
OMRON
Digital temperature controller program
E5AC-TQX4DSM-060
OMRON Digital temperature controller program E5AC-TQX4DSM-060
Size: 96 x 96mm. Control output 1: voltage.
OMRON
Digital temperature controller program
E5EC-TQX4DSM-080
OMRON Digital temperature controller program E5EC-TQX4DSM-080
Size: 48 x 96mm. Control output 1: voltage.
OMRON
Digital temperature controller program
E5AC-TCX4DSM-060
OMRON Digital temperature controller program E5AC-TCX4DSM-060
Size: 96 x 96mm. Control output 1: current.