Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points E5CN-R2HH03T-W-FLK Manual.
Remote SP input: there.
Transfer output: -.
Using large font PV display (white), improve visibility
E5CN-R2HH03T-W-FLK
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E5CN-R2HH03T-W-FLK Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication E5CN-R2HH03T-W-FLK Manual.
Combined temperature control device through component communication. In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application OMRON E5CN-R2HH03T-W-FLK User's Manual.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design OMRON E5CN-R2HH03T-W-FLK User's Manual.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise OMRON E5CN-R2HH03T-W-FLK User's Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with tthe step,
response method E5CN-R2HH03T-W-FLK Communications Functions.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
wwith reduced problems due to workpiece collisions E5CN-R2HH03T-W-FLK Manual.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature.