Name: Tape reflector.
Directional angle: 30° min.
Ambient operating temperature range: 0 to 40°C.
Ambient storage temperature range: -40 to 70°C.
Ambient operating humidity range: 35% to 85%.
Ambient storage humidity range: 35% to 85%.
Degree of protection: IEC IP67.
Accessories: --. Case color: Black E5EN-RY3BT-N User's Manual.
Control output: Relay output.
Control mode *1: Standard or heating/cooling
E5EN-RY3BT-N
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5EN-RY3BT-N User's Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-RY3BT-N User's Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON E5EN-RY3BT-N Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher) OMRON E5EN-RY3BT-N Manual.
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR) .
Functions: Heater burnout, No; Mounting option units, Yes OMRON E5EN-RY3BT-N Manual.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 2500 ms E5EN-RY3BT-N .
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E5EN-RY3BT-N User's Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.