Type of input: AC voltage input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K8AB-VS1 Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K8AB-VS1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceInput type: NPN/ voltage pulse input type K8AB-VS1 Manual.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K8AB-VS1 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximumHighly Visible LCD Display with 2-color (Red and Green) LEDs OMRON K8AB-VS1 User's Manual.
Wide input range - select from two types of platinum-resistance,
thermometers and ten types of thermocouples OMRON K8AB-VS1 User's Manual.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Temperature input shift and temperature unit selection functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate) OMRON K8AB-VS1 User's Manual.
Finger protective cover (standard equipment) protects against,
electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to conform to U.S. and Canadian requirements under,
the Component Recognition Program of UL.
CE marking. Type: Medium-sensitivity models.
Sensed current: 500 mA/1,000 mA(switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of iinsulation in,
electrical devices K8AB-VS1 .
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutuually compatible K8AB-VS1 Manual.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease.