Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XVD-L1AT11 User's Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-XVD-L1AT11
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVD-L1AT11 User's Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1 K3HB-XVD-L1AT11 User's Manual.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON OMRON K3HB-XVD-L1AT11 Manual.
Supports phase loss detection when the motor is operating.
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator OMRON K3HB-XVD-L1AT11 Manual.
Ideal to prevent reverse operation of motors. Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay OMRON K3HB-XVD-L1AT11 Manual.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weightt were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XVD-L1AT11 .
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-XVD-L1AT11 User's Manual.
External event input can be applied to a variety of measurement and identification situations.