Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AC-H13CC-FLK Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8AC-H13CC-FLK
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AC-H13CC-FLK Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment K8AC-H13CC-FLK Manual.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply OMRON K8AC-H13CC-FLK Communications Manual.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays OMRON K8AC-H13CC-FLK Communications Manual.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Product: Straight Bar Nozzle; 100 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance OMRON K8AC-H13CC-FLK Communications Manual. Function: Temperature monitoring.
Power supply voltage: 24 VAC/DC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequuence, and phase loss monitoring with,
the DIN 22 K8AC-H13CC-FLK . 5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmationn of output operation K8AC-H13CC-FLK Manual.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay.