Sensor type: Diffuse-reflective.
Sensing distance: 1 m.
Connection method: pre-wired.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications OMRON E5AC-CC2ASM-000 Manual.
Non-stop detection.
High quality and reliability
E5AC-CC2ASM-000
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling OMRON E5AC-CC2ASM-000 Manual.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON E5AC-CC2ASM-000 Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channnel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5AC-CC2ASM-000 lnstruction Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method E5AC-CC2ASM-000 lnstruction Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.