Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON E5AC-RR4DSM-008 lnstruction Manual.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input
E5AC-RR4DSM-008
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms OMRON E5AC-RR4DSM-008 lnstruction Manual.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON E5AC-RR4DSM-008 lnstruction Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output: NPN.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. 1M E32-T84SV type: environmental type; vacuum resistance,
Specialty: L word shape heat: 200,
Shape / detection distance (mm): 480; 630; 320 (130),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 2 (0.1),
Fiber element for meeting diversified needsSize: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: have.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety off applications E5AC-RR4DSM-008 Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5AC-RR4DSM-008 Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.