Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - OMRON E5CN-HR2HH03-FLK User's Manual.
Event input points: -.
Transfer output: -.
Communication: -
E5CN-HR2HH03-FLK
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) OMRON E5CN-HR2HH03-FLK User's Manual.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultTerminal type: Exposed-lead Models OMRON E5CN-HR2HH03-FLK User's Manual.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Streamlined Communications from.
Temperature Controller to PLC.
The E5ZN Modular Temperature Controller is connected to,
the DeviceNet networrk E5CN-HR2HH03-FLK MANUAL.
The I/O link function allows setting and monitoring (e.g., of,
present values) for the E5ZN Modular Temperature Controller to,
be performed without communications programming.
Up to 16 E5ZN Modular Temperature Controlllers can be,
connected to one Unit E5CN-HR2HH03-FLK MANUAL.
All the parameters for the E5ZN can be uploaded or download,
ed in one operation using DeviceNet Configurator.