Product model: E5ER-CT3DB-FLK
Name: PLC CPU
Brand: OMRON
Sort: Installation Guide
File language: English
File size: 3.69MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON PLC CPU Installation Guide.
Ideal for the thermal input devices of Temperature Controllers E5ER-CT3DB-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON PLC CPU Installation Guide.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON PLC CPU Installation Guide.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5ER-CT3DB-FLK Installation Guide.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5ER-CT3DB-FLK Installation Guide.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 E5ER-CT3DB-FLK Installation Guide. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.

Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5ER-CT3DB-FLK Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON PLC CPU Installation Guide.
Related products
OMRON
Digital regulator
E5ER-CTB-DRT
OMRON Digital regulator E5ER-CTB-DRT
Ontology: DeviceNet type. Size: 48 x 96mm. Ty
OMRON
Digital regulator
E5ER-CT3DB-FLK
OMRON Digital regulator E5ER-CT3DB-FLK
Ontology: asic. Size: 48 x 96mm. Type: asic
OMRON
Digital Controllers
E5AR-QC43DB-FLK
OMRON Digital Controllers E5AR-QC43DB-FLK
Size: 96 × 96 mm. Control type: Basic contro
OMRON
Digital regulator
E5ER-CT3DW-FLK
OMRON Digital regulator E5ER-CT3DW-FLK
Ontology: asic. Size: 48 x 96mm. Type: 2 in