Sensing method: Retro reflective.
Appearance: Horizontal.
Connection method: Standard M12 Connector.
Sensing distance: 1m [100 mm].
Model: PNP output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, -- OMRON E5EZ-C3 User's Manual.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards
E5EZ-C3 Lead wire length: 4m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON E5EZ-C3 User's Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Holder/bracket, Shaft (brace),
Bolt with hexagonal hole, Nut, Phillips screw, Slotted/Phillips screws;
Material, PBT (polybutylene tereph thalate), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304);
Count, 1, 1, 1, 1, 1, 2 OMRON E5EZ-C3 User's Manual.
Applicable sensor (mounting pitch on sensor side): E3Z (25.4),
E3S-R6@/R8@ (20) , E39-R3.
Page: Dimensions, 14. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaased,
Further performance improvement E5EZ-C3 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EZ-C3 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.