Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 35 A, 100 to 240 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks OMRON GX-MD3218 PROGRAMMING MANUAL.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
GX-MD3218
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track OMRON GX-MD3218 PROGRAMMING MANUAL.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC OMRON GX-MD3218 PROGRAMMING MANUAL.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 200 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the GG3NA Series GX-MD3218 Manual.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Prrotective cover for greater safety GX-MD3218 Manual.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)).