Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: DPST-NO.
Long-time range model (0.1 min to 10 h).
Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives OMRON Digital Controllers User's Manual
H7CN-XLNM Operating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: L Series (time range: 1.0 to 120 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Set two time ranges with each Timer, from 0 OMRON Digital Controllers User's Manual. 1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Control output: Contact output: DPDT (time-limit output).
Supply voltage: 110 VAC (50/60 Hz).
11-pin models.
Solid-state Timer with Valuable Multiple-time.
Ranges and Multiple-operating Modes.
Handles a wide range of applications through eight operating modes.
With H3BA-N8H models, the output type can be switched OMRON Digital Controllers User's Manual.
between time-limit DPDT and time-limit SPDT + instantaneous.
SPDT using a selector.
Setting rings (order separately) to enable consistent settings.
and to limit the setting range.
Panel Covers (order separately) to enable various panel H7CN-XLNM User's Manual.
designs.
CE marking.
UL, CSA and CCC certification, conforms to LR. Type: H5CZ.
Time specifications: 0 H7CN-XLNM User's Manual. 001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CN-XLNM User's Manual.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolateed for safety and reliability H7CN-XLNM Manual.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load OMRON Digital Controllers User's Manual.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.