Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) OMRON Digital Temperature Controllers Communications Manual
K3GN-NDC-L1-400
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Instantaneous type.
Current setting range: 20 to 65 A OMRON Digital Temperature Controllers Communications Manual.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button OMRON Digital Temperature Controllers Communications Manual.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction K3GN-NDC-L1-400 Communications Manual.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3GN-NDC-L1-400 Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type of input: AC voltage input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL) K3GN-NDC-L1-400 Communications Manual.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3GN-NDC-L1-400 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub presssure gauge for monitoring the operation trend OMRON Digital Temperature Controllers Communications Manual.
External event input can be applied to a variety of measurement and identification situations.
DeviceN