Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified OMRON K3GN-NLC Manual
K3GN-NLC
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputModel: UPR (91L).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched OMRON K3GN-NLC Manual.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system OMRON K3GN-NLC Manual.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1a, DC; closed circuit 110V 15A 1C 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: MMount Searl N1 K3GN-NLC User's Manual. 5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjjustment, easy to coordinate K3GN-NLC User's Manual.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment.