Ideal for water level control.
Sensitivity adjustment and timer for easy usage.
Sensitivity adjustment from 10 k to 100 kΩ.
Enables easy onsite adjustment.
ON-delay timer from 0.1 to 10 s.
Ideal as countermeasure for waves on liquid surfaces.
Width of 17.5 mm to reduce space required in panels OMRON Digital Temperature Controllers Communications Manual.
Push-In Plus Terminal that reduce wiring work
K3HB-RNB
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models with transistor outputs added for low contact wear. Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V OMRON Digital Temperature Controllers Communications Manual.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the most up to 50kHz of high-speed pulseSetting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC OMRON Digital Temperature Controllers Communications Manual.
Power supply voltage: 100 to 240 VAC K3HB-RNB Communications Manual.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages K3HB-RNB Communications Manual.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator K3HB-RNB Communications Manual.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-savving, integrated construction K3HB-RNB Manual.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Digital Temperature Controllers Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.