Product model: K3HB-XAD-L2AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 1.83MB
Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified OMRON K3HB-XAD-L2AT11 Manual K3HB-XAD-L2AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurementRated primary current: 100 A OMRON K3HB-XAD-L2AT11 Manual.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function OMRON K3HB-XAD-L2AT11 Manual.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 poinnts through the speed, time, or cycle of the digital time interval table K3HB-XAD-L2AT11 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Meaasuring, calculating and displaying the pulse interval between 2 points K3HB-XAD-L2AT11 Communications Manual.
Pulse interval measurement range, the maximum can be measured from 10ms to 320
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-CPAC11 AC100-240
Type of input: AC current input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC100-240
Type of input: AC current input. Output type
OMRON
Time interval table
K3HB-PPB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-L2AT11 AC/DC24V
Input type: PNP input type. Event input term