Product model: K8AC-H22PC-FLK
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 7.32MB
Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages OMRON K8AC-H22PC-FLK Communications Manual.
Manual resetting and automatically resetting supported by one Relay K8AC-H22PC-FLK
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC OMRON K8AC-H22PC-FLK Communications Manual.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload OMRON K8AC-H22PC-FLK Communications Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,

Can correspond to the rated value of all generators K8AC-H22PC-FLK Manual.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy. Sharing with voltage input, no need to control the power suppply K8AC-H22PC-FLK Manual.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED.
Related products
OMRON
Digital Heater Element Burnout Detector
K8AC-H23PC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H23PC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H23PN-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H23PN-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H22CC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H22CC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H21CN-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H21CN-FLK
Power supply voltage: 100 to 240 VAC. Heater