Reliable Detection of Transparent,
Objects, Including Thin-walled Clear,
Plastic Bottles.
Uses OMRON''s unique optical system ("Inner View") that can,
detect various shapes of clear, plastic bottles.
Detects a wide range of bottles from 500-ml bottles to 2-l bottles,
and from single bottles to sets of stocked bottles E5DC-CX2DSM-015 Basic Type".
Provides a high degree of protection (IP67), mutual interference,
prevention, and EN standard compliance
E5DC-CX2DSM-015 Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5DC-CX2DSM-015 Basic Type".
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5DC-CX2DSM-015 Basic Type".
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON E5DC-CX2DSM-015 Manual. Name: Basic Unit(gradient temperature control)(See note 1 OMRON E5DC-CX2DSM-015 Manual. ).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3 OMRON E5DC-CX2DSM-015 Manual. ); Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups E5DC-CX2DSM-015 .
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5DC-CX2DSM-015 Basic Type". ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.