Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Applicable Sensor Communications Unit: E3X-ECT; E3X-CRT.
Easy and optimum settings for anyone E5CN-HC203-FLK.
Smart Fiber Amplifier Unit with Long-term Stable Detection.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button
E5CN-HC203-FLK
Highly usable design enables anyone to configure the settings easily.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity E5CN-HC203-FLK.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II).
The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling E5CN-HC203-FLK.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive .
Lead wire length M : 2m.
A Wide Variety of High-precision.
Tempperature Sensors E5CN-HC203-FLK.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HC203-FLK.