Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 50.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed 3G2A5-AD003 Manual. Specification: three phase 200V
3G2A5-AD003
Power: 0.4KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 3kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G2A5-AD003 Manual.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in 3G2A5-AD003 Manual.
Protection function. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option OMRON PROXIMITY SWITCH Manual. Function name: single phase 200V.
Power: 0.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) OMRON PROXIMITY SWITCH Manual.
Built in brake unit (brake resistance needs to be matched).
Weight: 1.0KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):109mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication OMRON PROXIMITY SWITCH Manual.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:20008 EN (Cat 3G2A5-AD003 SETUP MANUAL. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Frequency converter input power: 3 phase AC400V.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonicc currents generated by a transducer 3G2A5-AD003 Manual.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor.