When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Level: 3 phase 400V level 3G3AX-RX-CRT-E Communications Manual.
Connecting resistance: 34 or more.
Internal resistance value: 120W, 180W * 2 (series) 3G3AX-RX-CRT-E
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter. Specification: three phase 400V 3G3AX-RX-CRT-E Communications Manual.
Power: 11KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 6kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact 3G3AX-RX-CRT-E Communications Manual.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Inverter input power: 3 phase / single phase AC200V.
Weight: 0.8KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Specifications: Standard type.
Impact resistance: 400W.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. Specification: three phase 400V.
Power: 7.5KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced air cooling.
Weight: 4.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as welll as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3AX-RX-CRT-E Manual.
Covers the special features of the fan pumpp class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice 3G3AX-RX-CRT-E Manual.
Related products
OMRON
Brake resistance
3G3AX-RBA1203
OMRON Brake resistance 3G3AX-RBA1203
Specification: small. Impact resistance: 120W
OMRON
Brake resistance
3G3AX-RBA1201
OMRON Brake resistance 3G3AX-RBA1201
Specification: small. Impact resistance: 120W
OMRON
Brake resistance
3G3AX-RBC6001
OMRON Brake resistance 3G3AX-RBC6001
Specification: medium capacity type. Impact r
OMRON
Brake resistance
3G3AX-RBB2002
OMRON Brake resistance 3G3AX-RBB2002
Specifications: Standard type. Impact resista