Name: Compact Connectors.
Specifications: Outputs; 2 outputs; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices C200H-MC221 HOST CONNECTION MANUAL.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price
C200H-MC221
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Model : C500-PS222-E.
Expansion I/O Backplane Power Supply
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5 VDC C200H-MC221 HOST CONNECTION MANUAL. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs C200H-MC221 HOST CONNECTION MANUAL.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Model: CPM2C-20CDTC-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Name: Bit Slave Units with e-CON Connectors.
Specifications: Inputs; 2 inputs; PNP.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied ffrom the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection C200H-MC221 Manual.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits C200H-MC221 Manual.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.