Model: CPM2C-10C1DR-D. CPU Unit: Units with 10 I/O points.
I/O terminal block.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: Yes.Model : C500-LK201-EV1.
RS-232C/RS-422.Name: Connector.
Model: C200H-CE002.Name: Compact Connectors.
Specifications: Outputs; 2 inputs; NPN CJ1H-CPU65H-R HOST CONNECTION MANUAL.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery
CJ1H-CPU65H-R
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price CJ1H-CPU65H-R HOST CONNECTION MANUAL.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Power supply: DC power supply.
Output method: Relay output.
Inputs points: 12 points.
Outputs points: 8 points.C500-DA Special I/O Unit Analog Output C500-DA501.
Output: 8 pts.
Specification: 0~+5V, 0~+10V, -5~+5V
-10~+10V, 0~+20mA, 4~+20mA.Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units CJ1H-CPU65H-R HOST CONNECTION MANUAL.
Specifications: Output type, Sourcing;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current, 24VDC, 7mA,
24VDC, 0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 24 points.
Outputs points: 16 points.Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CJ1H-CPU65H-R Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1H-CPU65H-R Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.