Specifications: 2 × RS-232C ports, protocol macro function.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-422A/485 ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave CJ1M-CPU11 HOST CONNECTION MANUAL
CJ1M-CPU11
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1M-CPU11 HOST CONNECTION MANUAL. Supply voltage: 100 or 230 V AC (selectable), 50/60 Hz.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note).Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 CJ1M-CPU11 HOST CONNECTION MANUAL.
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Model: C200H-B7A02.
I/O points: 32 output points.
Weight: 300g max.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ1M-CPU11 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1M-CPU11 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.