CV500-CN Cable Motion Control Connecting Cables 4 m CV500-CN424Power supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 6 points.
Outputs points: 4 points.C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS02-V1.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit CJ1W-EIP21 PROGRAMMING MANUAL.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output
CJ1W-EIP21
Signal range, Resolution: 4 to 20mA;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 170mA max CJ1W-EIP21 PROGRAMMING MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.17*3.
Standards: UC1, N, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CS1 Special I/O Units CJ1W-EIP21 PROGRAMMING MANUAL.
Product name: Isolated-type,
2-Wire Transmitter Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-EIP21 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-EIP21 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.