CPU Unit: CP1L-M CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 24; Output, 16 CJ1W-NC414 .
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet
CJ1W-NC414
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Supply voltage: 24 VDC
Operating voltage range: 20.4 to 28.8 VDC
Power consumption: 100 W max CJ1W-NC414 .
Output capacity: 12 A, 5 VDCC200HW Communications Interface Module C200HW-PRM21Model: C200HW-COM05-V1.
Specifications: Two RS-232C ports and a protocol macro function.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks CJ1W-NC414 .
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-232C ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.28A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol. Unit type: CS1 CPU Bus Unit.
Product name:Ethernet Units.
Specifications: Communi cations cable,
100BASE TX Cable; Communications functions,
FINS communications service(TCP/IP and UDP/IP),
FTP server function, socket service,
mail send service, mail reception,
(remote command reception),
auto-adjustment of PLC''s internal clock,
and server host name specificatioon;
Duplexing, Not supported;
Units per CPU Unit, 4 Units CJ1W-NC414 OPERATION MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.38A; 26V, --.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Managemment CJ1W-NC414 OPERATION MANUAL.
Select the required communications,
services according to application needs,
to flexibly integrate PLCs with an,
Ethernet information network.