Applicable CPU Units: CQM1H-CPU51/61.
Serial Communica-tions ports>Port 1: RS-232C: 19.2 kbps max., 15 m max.
Serial Communica-tions ports>Port 2: RS-422A/485: 19.2 kbps max., 500 m max.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
Name: PID Control Module.
Model: C200H-PID03 CJ1W-NC471 OPERATION MANUAL.
Output: Current output.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV103
CJ1W-NC471
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Current output(transistor output used for cooling outputs).Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
320 points/10 Units (No Expansion Rack); Program capacity,
10K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CJ1W-NC471 OPERATION MANUAL. 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT201 CJ1W-NC471 OPERATION MANUAL.
Master station unit remote I/O.CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 200 VAC CV500-FHD02-E.Output method: Transistor sinking.
Inputs: 12.
Outputs: 8.Model: CPM2C-32EDTC. Units with 32 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Model: CPM2A-40CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 24 points.
Outputs points: 16 points.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 224V,-- CJ1W-NC471 Manual.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1W-NC471 Manual.