Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-422A/485 ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave CP1E-N30DR-A Software.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0
CP1E-N30DR-A38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CP1E-N30DR-A Software. Model: C200HW-BI051.
No. of I/O slots: 5 slots.CV500-HD SYSMAC BUS PC Unit Hard Disk Drive For 200 VAC CV500-HDD02.C200HS-CPU21-E CPU
High Performance, Small Rack Style, Built-in RS-232C Port
The C200HS-CPU21-E and C200HS-CPU23-E controllers offer some of the same basic functionality as models C200H-CPU01-E/CPU03-E.
These controllers have the added capabilities ideally suited for high speed machine control,
which includes larger memory,
larger instruction set,
and increased speed CP1E-N30DR-A Software. Name: CS1D Duplex Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Not supported.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Model : CV1000-DM251.
Available CV1000/2000/CVM1-CPU21-V2.
256K words.Name: CJ1 Special I/O Unit.
Specifications: Type of communications,
Remote I/O communications, Message communications;
Maximum number of I/O points per Master Unit,
Word Slave Units: 1,024 inputs and 1,024 outputs,
(2,048 I/O points total)Bit Slave Units:
256 inputs and 256 outputs (512 I/O points total).
No. of unit numbers alloccated: 1, 2, 4, or 8 CP1E-N30DR-A OPERATION MANUAL.
Current consumption : 5V, 0.4A; 24V,--.
Standards: CE, U, U1, L, N.
NJ/CJ-series CompoNet Master Units Increase,
the Range of Applicability of Sensors and Actuators.
The NJ/CJ-series CompoNet Master Unit manages,
the CompoNet network, controls communications,
between the Controller and Slave Units,
and handles I/O data and message data CP1E-N30DR-A OPERATION MANUAL.