Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CP1E-N30DR-A USER'S MANUAL.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CP1E-N30DR-A
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. CPU Unit: CP1L-L CPU Units with 10 Point CP1E-N30DR-A USER'S MANUAL.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 6; Output, 4.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port CP1E-N30DR-A USER'S MANUAL.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Analog outputs : 2 points.
Power supply : built-in power supply
Ranges : -10 to + 10V or 0 to 20mAProduct name: CS1 Expansion Backplanes.
Specifications: For both CS/C200H-series,
Units; 3 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: CJ1 Special I/O Unit.
Specifications: Type of communications,
Remote I/O communications, Message communications;
Maximum number of I/O points per Master Unit,
Word Slave Units: 1,024 inputs and 1,024 outputs,
(2,048 I/O points total)Bit Slave Units:
256 inputs and 256 outputs (512 I/O points total).
No. of unit nummbers allocated: 1, 2, 4, or 8 CP1E-N30DR-A Manual.
Current consumption : 5V, 0.4A; 24V,--.
Standards: CE, U, U1, L, N.
NJ/CJ-series CompoNet Master Units Increase,
the Range of Applicability of Sensors and Actuators.
The NJ/CJ-series CompoNet Master Unit manages,
the CompoNet network, controls communications,
between the Controller and Slave Units,
and handles I/O data and message data CP1E-N30DR-A Manual.