Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 150 VA max.
Output capacity: 8 A, 5 VDCUnit type: CS1 Basic I/O Units.
Product name: DC Input/Transistor Output Unit.
Specifications: 24 VDC, 6 mA 32 inputs CP1E-N40S1DT1-D PROGRAMMING MANUAL.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No
CP1E-N40S1DT1-D
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CP1E-N40S1DT1-D PROGRAMMING MANUAL. Output method: Relay.
Inputs: ---.
Outputs: 8.Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CP1E-N40S1DT1-D PROGRAMMING MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. C200HW Communications Interface Module C200HW-PRM21Model: C200H-DA002.
Input points: 4.
Voltage input: –10 to 10V.
Current input: 4 to 20 mA.Model: C200H-ID501.
No. of inputs: 32 pts.
Specifications: 5 VDC.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems CP1E-N40S1DT1-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40S1DT1-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.