24 VDC.Data Setting Console Connecting Cable, For C200H-DSC01.
2MInputs: 8I/O link input bits.
Outputs: 8I/O link input bits.Number of outputs: 8 pts.
Max. switch-ing capacity: 2 A at 24 V DC.
External connector: Terminal block.
Weight: 200 g max.C200HW Communications Interface Module C200HW-PRM21CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223-E CP1E-N40DR-A USER'S MANUAL.
4-MB memory; w/floating-point processor
CP1E-N40DR-AModel: C500-COV03.
C500 I / O Control Unit, I / O Interface For unitUnit type: CJ1 Basic I/O Units.
Product name: TTL I/O Units.
Specifications: Output type, --;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 5VDC, 35mA,
5VDC, 35mA;
Commons, 16 points, 1 common;
External connection, MIL connector CP1E-N40DR-A USER'S MANUAL.
No. of words allocated: 4 words.
Current consumption: 5V, 0.19A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. For 3-slot Backplane.Power supply: AC power supply CP1E-N40DR-A USER'S MANUAL.
Output method: Transistor output source type.
Inputs points: 24 points.
Outputs points: 16 points.Model: C500-CE401.
Solder pin connector cover 40PProduct name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 8; Outputs, 6;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: CJ1 Special I/O Unit.
Specifications: Type of communications,
Remote I/O communications, Message communications;
Maximum number of I/O points per Master Unit,
Word Slave Units: 1,024 inputs and 1,024 outputs,
(2,048 I/O points total)Bit Slave Units:
256 inputs and 256 outputs (512 I/O points total).
No. of unit nummbers allocated: 1, 2, 4, or 8 CP1E-N40DR-A Manual.
Current consumption : 5V, 0.4A; 24V,--.
Standards: CE, U, U1, L, N.
NJ/CJ-series CompoNet Master Units Increase,
the Range of Applicability of Sensors and Actuators.
The NJ/CJ-series CompoNet Master Unit manages,
the CompoNet network, controls communications,
between the Controller and Slave Units,
and handles I/O data and message data CP1E-N40DR-A Manual.