Unit type: CJ1 Basic I/O Units.
Product name: Relay Contact Output Units.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC/24VDC, 2A;
Commons, Independent contacts;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0 CP1H-Y20DT-D . 09A; 24V, 0.048A max.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications
CP1H-Y20DT-D
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput CP1H-Y20DT-D . I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.CPU Unit: CP1L-EM CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sinking);
Inputs, 24; Output, 16 CP1H-Y20DT-D .
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of connecting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.2 thermocouple inputsName: External Connector.
Model: C500-CE404.
Specifications: Solder terminal; 40p and a Connector Cover (Horizontal-type).I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.Name: MIL Connector Type.
Specifications: Analog inputs; 4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reducced CP1H-Y20DT-D OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1H-Y20DT-D OPERATION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.