C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD007(3G2A5-AD007).
Input: 4 pts.
Specification: 0~+10V.Model: CPM2C-10C1DTM-D. CPU Unit: Units with 10 I/O points.
2 MIL connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: Yes.Power supply: DC power supply CP1L-L10DT1-D INSTRUCTIONS REFERENCE MANUAL.
Output method: Transistor output sink type
CP1L-L10DT1-D
Inputs points: 18 points.
Outputs points: 12 points.Number of inputs: 32 pts.
Input Voltage: 24V DC.
Input Current: 6 mA.Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Single CPU System only;
Number of Power Supply Units, 2 Units max.
(for duplex operation);
Number of I/O Units, 8 slots max.
Current consumption: 5V system, 0 CP1L-L10DT1-D INSTRUCTIONS REFERENCE MANUAL. 17A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet CP1L-L10DT1-D INSTRUCTIONS REFERENCE MANUAL.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV002.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Voltage output(transistor output used for cooling outputs).Model: C200H-MP831.
Description: EPROM, 8K words, no clock.Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 16 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 11/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max CP1L-L10DT1-D Manual.
(Settable to 1 ms/point).
Externa connection, MIL connector.
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
Anaalog Input Units for converting,
analog input signals into binary data CP1L-L10DT1-D Manual.
Analog Output Units for converting ,
binary data into analog output signals.