Required for Analog Input and Output Units: For one Analog Unit.Model: C200H-TS002.
Temperature sensor: Thermocou-ples: K (CA)/L (Fe-CuNi)(DIN)(selectable)
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected)Specification: Platinum resistance thermometer input (Pt, JPt),
ON/OFF or advanced PID control,
tran-sistor (PNP) output, 2 loops CQM1H-II101 System Manual. Product name: Pulse I/O Module
CQM1H-II101
Specifications: Sourcing outputs, MIL connector,
10 inputs (including four interrupt/quickresponse,
inputs and two high-speed counter inputs)6 outputs,
(including two pulse outputs and two PWM outputs).
Current consumption (A): 5V, 0.08; 24V,--.
Standards: UC1, N, L,CE.
CJ2M for basic machine automation CQM1H-II101 System Manual.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU.C500-ID I/O Unit DC Input 32 pts C500-ID218CN(3G2A5-ID218CN).
DC12-24V 10mA.Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (NPN) output, 2 loops CQM1H-II101 System Manual. Power supply voltage AC100 ~ 240V (wide range)
Output capacity: DC5V 4.6A, with a replacement time notification.C500-RM SYSMAC BUS Remote I/O Master Wired C500-RM001-PV1.
APF/PCF.Peripheral port to RS-422 conversion cable (length: 0.2 m).Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Host Link Module.
Model: C200H-LK201-V1.
Communication ports: 1 RS-232C, 25 pin female.Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CQM1H-II101 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CQM1H-II101 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.