CPU Unit: CP1H-XA CPU Units.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Analog inputs: 4, Analog outputs: 2;
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 24; Output, 16 CRT1-OD16S-1 REFERENCE MANUAL.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller
CRT1-OD16S-1
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. I/O points: 256 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 3 K.
RS-232C port: no.Feeding unit while the SYSMAC LINK Unit 2
If you need to CRT1-OD16S-1 REFERENCE MANUAL. C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA002(3G2A5-DA002).
Output: 2 pts.
Specification: 0~+10V.C200HS-CPU01-E CPU
High Performance, Small Rack Style
The C200HS-CPU01-E and C200HS-CPU03-E controllers offer some of the same basic functionality as models C200H-CPU21-E/CPU23-E.
These controllers have added capabilities ideally suited for high speed machine control,
which includes larger memory,
larger instruction set,
and increased speed CRT1-OD16S-1 REFERENCE MANUAL. Name: CS1D Duplex Unit.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Supported.
Current consumption: 5V system, 0.41A;
26 V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. CV500-BS CPU Bus Unit BASIC Unit CV500-BSC61.
RS-232C: 1 port.
GP-IB: 1 port.
(w/EEPROM).Model: CPM2C-20C1DR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: Yes.Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced CRT1-OD16S-1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-OD16S-1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.