Product name: N@@S1- type CPU Units with 60 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 36; Outputs, 24;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE CS1D-CPU65H .
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CS1D-CPU65H
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0 CS1D-CPU65H . 1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Emergency stop unit: 2 inputs/2 outputs, 4 general-purpose inputs.Model: C200H-OD216.
No. of points: 8 pts.
Specifications: 0 CS1D-CPU65H . 8 A, 24 VDC. source type (PNP). with load short protection.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV003.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Current output(transistor output used for cooling outputs).C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD005(3G2A5-AD005).
Input: 2 pts.
Specification: -5~+5V.Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit.
For 2 Unit.Unit classification: CJ1 CPU Bus Unit.
Specifications:Equipped with Master,
and Slave functionality.
Controls for up to 32,000 points per Master.
Communications:Remote I/O Communications,
Master (fixed allocations or user-set,
allocations) Remote I/O Communications,
Slave (fixed allocations or user-set,
allocations) Message communica29A; 24V,--.
Smallest in the Industry!
A DeviceNet Unit for the,
CJ Series that Boasts Industry-leading,
Performance and Functions.
Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduuced CS1D-CPU65H OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1D-CPU65H OPERATION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.