Actuator: Roller plunger (Metal roller).
Cable length: 5 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch DRT2-OD08CL-1 OPERATION MANUAL.
Built-in switches with two- or four-contact construction are available
DRT2-OD08CL-1
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: 1 A at 30 VDC.
LED indicator: Without indicator.
Actuator: Plastic rod.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector DRT2-OD08CL-1 OPERATION MANUAL.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models DRT2-OD08CL-1 OPERATION MANUAL. ) Actuator: Roller plunger (Metal roller).
Cable length: 5 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 2NC (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type of drive rod: plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NNC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC DRT2-OD08CL-1 Manual.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability DRT2-OD08CL-1 Manual.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.