Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AC-CX2ASM-000 lnstruction Manual.
Ideal for the thermal input devices of Temperature Controllers
E5AC-CX2ASM-000
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output 1: Voltage output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: -- E5AC-CX2ASM-000 lnstruction Manual.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5AC-CX2ASM-000 lnstruction Manual.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Model: Shielded, M30.
Sensing distance: 10 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Size: 96 × 96 mm.
Control type: 4-loop control .
Control mode: 4-loop standard control, 2-loop heating and cooling control.
Outputs(control/transfer): 4 points: Current output (4 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using modells with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AC-CX2ASM-000 Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5AC-CX2ASM-000 Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.