Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5AC-QQ2DSM-011 RS-485 CompoWay/F.
Event input points: -
E5AC-QQ2DSM-011
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5AC-QQ2DSM-011 RS-485 CompoWay/F.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5AC-QQ2DSM-011 RS-485 CompoWay/F. , can be a key operation. Appearance: Standard.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Dark-ON.
Indicator mode: Incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC. Appearance: Unshielded, M30.
Sensing distance: 15 mm.
Output configuration: DC 3-wire, PNP.
Model: Operation mode, NC.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (ssold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5AC-QQ2DSM-011 lnstruction Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5AC-QQ2DSM-011 lnstruction Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).