Classification: Exclusive Models.
Description: Double-element model.
Temperature range (See note 3.): 0°C to 900°C.
Element type: K (CA).
Conductor type: Two nongrounded types.
Class: 2 (0.75).
Protective tubing material: ASTM316L.
Terminal type: Exposed lead wires.
Page: 27.
A Wide Variety of High-precision E5AN-C3T-W-N Basic Type".
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E5AN-C3T-W-N
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AN-C3T-W-N Basic Type". Sensor type: Diffuse-reflective.
Sensing distance: 100 mm.
Connection method: M12 connector.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability E5AN-C3T-W-N Basic Type".
High EMC protection.
High light immunity.
Robust and waterproof housing. Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 200 mm.
Functions: Timer Self Diagnosis Turbo.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Sensing method: Convergent reflective.
Connection method: Pre-wired (2 m).
Sensing distance : 20 to 35 mm .
function Timer: With .
Model: PNP output.
Reliable Detection Unaffected by PCB.
Holes or Notches.
High-limit E3S-LS3@ is suitable for incorporation in devices.
Wide-range E3S-LS3@W is ideal for detecting tall components,
mounted on boards.
Timer function models available. Ultra small rotary encoder (diameter 20), incremental.
Machine built in mini 1046.
The size and resolution of 1000P/R diameter 20mm.
Axle and hollow shaft type. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5AN-C3T-W-N Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault