Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None E5AN-HSS2HHBFM-500 Basic Type".
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None
E5AN-HSS2HHBFM-500
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature E5AN-HSS2HHBFM-500 Basic Type".
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5AN-HSS2HHBFM-500 Basic Type". ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual,, RUN/STOP, alarm), interactive display PV/SV E5AN-HSS2HHBFM-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-HSS2HHBFM-500 Manual.