Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application E5AR-TQE3MB-FLK OPERATION MANUAL.
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used
E5AR-TQE3MB-FLK
Simple operation and settings. Even simpler with digital models. Sensor method: Throughbeam.
Case material: Polybutylene terephthalate.
material Sheath: PVC.
Connection method: Pre-wired cable (2 m).
Sensing distance: 0.2 to 3 m.
Output: PNP.
Detects Intrusions into Hazardous.
Areas with a Single Beam and E5AR-TQE3MB-FLK OPERATION MANUAL.
Complies with International Safety.
Standards. Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5AR-TQE3MB-FLK OPERATION MANUAL.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M12 connector.
Body material: Stainless steel.
Thread length (overall length): 27 (43).
Output configuration: NPPN E5AR-TQE3MB-FLK Manual.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated E5AR-TQE3MB-FLK Manual.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.