Item: Analog output.
Functions: Analog output.
Model: NPN output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m).
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter E5CC-CX3ASM-007 INSTRUCTION MANUAL.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor
E5CC-CX3ASM-007
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- E5CC-CX3ASM-007 INSTRUCTION MANUAL.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 E5CC-CX3ASM-007 INSTRUCTION MANUAL. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5CC-CX3ASM-007 Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault