Sensing method: Retro reflective.
Appearance: Vertical.
Connection method: Standard M12 Connector.
Sensing distance: 1m [100 mm].
Model: PNP output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, -- E5CN-CQ2BL USER'S MANUAL.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards
E5CN-CQ2BL Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications E5CN-CQ2BL USER'S MANUAL. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: shield, M18.
Detection range: 7mm.
Action mode: NO. Appearance: Standard.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs) E5CN-CQ2BL USER'S MANUAL.
Connection method (Cable length): Pre-wired model with standard cable (1 m).
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic // manual, RUN/STOP, alarm), interactive display PV/SV E5CN-CQ2BL Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-CQ2BL Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.