Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HR2H01-FLK Manual E5CN-HR2H01-FLK Basic Type Basic Type

OMRON E5CN-HR2H01-FLK Manual E5CN-HR2H01-FLK Basic Type Basic Type

Product model: E5CN-HR2H01-FLK
Name: OMRON E5CN-HR2H01-FLK Manual E5CN-HR2H01-FLK Basic Type Basic Type
Brand: OMRON
Sort: Basic Type Basic Type
File language: English
File size: 6.14MB
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5CN-HR2H01-FLK Basic Type".
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E5CN-HR2H01-FLK
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5CN-HR2H01-FLK Basic Type".
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CN-HR2H01-FLK Basic Type".
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adappter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5CN-HR2H01-FLK Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5CN-HR2H01-FLK Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
Related products
OMRON
High performance temperature controller
E5CN-HR2H03-FLK
OMRON High performance temperature controller E5CN-HR2H03-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2
OMRON High performance temperature controller E5CN-HR2
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Programmed temperature controller
E5CN-HTQ2H01-FLK
OMRON Programmed temperature controller E5CN-HTQ2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HR2D-W
OMRON High performance temperature controller E5CN-HR2D-W
Size: 48 x 48mm. Body: terminal type. Type: c