The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CN-HR2HH03D-FLK User's Manual.
Event input points: -.
Transfer output: -.
Communication: -
E5CN-HR2HH03D-FLK
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-HR2HH03D-FLK User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: Shielded, M8.
Sensing distance: 1.5 mm.
Output: Polarity Pin allocations: 1-4.
Operation mode: NO.
Highly Durable Proximity Sensor for.
Tough Environments E5CN-HR2HH03D-FLK User's Manual.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. Appearance: Unshielded, M18.
Sensing distance: 14 mm.
Model: Operation mode, NO.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HR2HH03D-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HR2HH03D-FLK Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.