LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTQ2H03-FLK Basic Type E5CN-HTQ2H03-FLK Programmable Type Manual

OMRON E5CN-HTQ2H03-FLK Basic Type E5CN-HTQ2H03-FLK Programmable Type Manual

Product model: E5CN-HTQ2H03-FLK
Name: OMRON E5CN-HTQ2H03-FLK Basic Type E5CN-HTQ2H03-FLK Programmable Type Manual
Brand: OMRON
Sort: Programmable Type Basic Type
File language: English
File size: 1.19MB
Type: Standard models.
Control output: ON/OFF output.
Model: NPN output.
The Ultimate Fiber Amplifier for.
Maximum Ease of Use and High.
Performance. Size: 48 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 4.
Communication: -.
Disconnection detection: 1 E5CN-HTQ2H03-FLK Basic Type".
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program E5CN-HTQ2H03-FLK
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set E5CN-HTQ2H03-FLK Basic Type".
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication E5CN-HTQ2H03-FLK Basic Type".
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtther performance improvement E5CN-HTQ2H03-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-HTQ2H03-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Programmed temperature controller
E5CN-HTQ2BF
OMRON Programmed temperature controller E5CN-HTQ2BF
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQ2H01D-FLK
OMRON Programmed temperature controller E5CN-HTQ2H01D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTQ2
OMRON Programmed temperature controller E5CN-HTQ2
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQ2BFD
OMRON Programmed temperature controller E5CN-HTQ2BFD
Size: 48 48mm, terminal type. Type: control