The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CN-R2MTD-500 USER'S MANUAL.
Event input points: -.
Transfer output: output (using control output)
E5CN-R2MTD-500
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-R2MTD-500 USER'S MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Appearance: Flat Unshielded.
Sensing distance: 10 mm[4 to 10 mm *].
Output configuration: DC 3-wire NPN.
Model/Operation mode: NO E5CN-R2MTD-500 USER'S MANUAL.
Flat Capacitive Sensor with a.
Thickness of Only 10 mm.
Flat Sensor with excellent space efficiency.
(Model with built-in Amplifier is only 10 mm thick.)
Direct mounting onto a metallic surface is possible. Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remoote SP input, suitable for a wide range of applications E5CN-R2MTD-500 Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5CN-R2MTD-500 Manual.
A new type of proportional control allows you to control the valve.