The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply E5EC-CC2ASM-014 lnstruction Manual
E5EC-CC2ASM-014
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5EC-CC2ASM-014 lnstruction Manual.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm E5EC-CC2ASM-014 lnstruction Manual.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 20 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5EC-CC2ASM-014 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EC-CC2ASM-014 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.